Battery test chamber are special designed for different type of traction battery test. On the basis of standard climatic chamber, protection mechanisms are provided to different hazard level, to ensure the safety of company personnel, property and equipment.
Utilize wind field simulation optimization and high uniformity inside the box
Special refrigeration design, energy-saving equipment
Strong product versatility
High fire safety level
MAIN SPECIFICATIONS
Type
TOD-B390EX
TOD-B546EX
TOD-B784EX
TOD-B1190EX
Interior Dimensions (W*D*Hmm)
1000*600*650
1200*650*700
1400*800*700
1700*1000*700
Temperature Range
-40~100℃
Heating Rate
≥ 3℃/min(-40~100℃)
Temperature Uniformity
≤1℃ (-40℃~+100℃,unloaded)
Temperature Deviation
≤±1℃ (-40℃ ~ +100℃)
Temperature Fluctuation
≤±0.5℃ (unloaded)
Humidity Fluctuation
≤±1℃ (-40℃ ~ +100℃)
Temperature Accuracy
0.1℃
Noise
≤69dB
Test Hole
Right side 100mm*2
Sample Rack Specification
50kg/ layer 2 layers on each side
Fire Protection
Safety Measures: Pressure relief, door chain (standard), strong exhaust (optional). Monitoring Functions (optional): Smoke detection, gas detection (CH, CO, H2), overtemperature
protection. Fire Extinguishing Capabilities (optional): Perfluorohexane, water spray, water submersion. Safety Programmable Logic Controller (PLC) (optional): Manual/automatic fire suppression, remote
fire suppression, independent alarm power cut-off.
137,139,143,144,146,147,148
Application Scenarios
Constant temperature and humidity chamber
Delivered 4 constant temperature and humidity chambers and 1 rapid temperature change chamber to a customer in Vietnam for testing battery structural parts and electronic devices, with stable performa
Constant temperature and humidity chamber
Delivered more than 50 devices to the world's leading laser radar brands, used for laboratory DV PV verification, performance testing, and reliability testing. Also used for product offline HT testing
Battery test chamber are special designed for different type of traction battery test. On the basis of standard climatic chamber, protection mechanisms are provided to different hazard level, to
Climate chamber are special designed for different type of traction battery test, On the basis of standard climatic chamber, protection mechanisms are provided to different hazard level, to ensure the
What is the temperature and humidity range of the unit?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
What are the cooling water inlet pressure and temperature requirements?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
What is the inlet pressure requirement for the impact chamber?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
What are the cooling water inlet pressure and temperature requirements?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
About how often should I change the humidity tampons?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.