Battery test chamber are special designed for different type of traction battery test. On the basis of standard climatic chamber, protection mechanisms are provided to different hazard level, to ensure the safety of company personnel, property and equipment.
Utilize wind field simulation optimization and high uniformity inside the box
Special refrigeration design, energy-saving equipment
Strong product versatility
High fire safety level
MAIN SPECIFICATIONS
Type
TOH-B1000EXL
TOH-B1200EXL
Interior Dimensions (W*D*Hmm)
1000*1000*1000
1000*1200*1000
Temperature Range
-40~100℃
Humidity range
20~98%RH
Heating Rate
(+20~100℃) ≥3℃/min
Cooling Rate
(+20~-40℃) ≥1℃/min
Temperature Uniformity
≤1℃
Humidity Deviation
±3.0%RH(>75%RH); ±5.0%RH(≤75%RH)
Temperature Deviation
≤±2℃
Temperature Fluctuation
≤±0.5℃
Humidity Fluctuation
≤±2.0%RH
Temperature Accuracy
0.1℃
Humidity Accuracy
0.1%RH
Output voltage
Charging: 0-5V Discharging: 1.5-5V (battery terminal voltage) Output line within 5 meters
Output current
-300A to +300A1-450A to +450A1-600A to +600A
Number of channels/per incubator
8CH
Voltage accuracy
±0.02%FS.(15°C-35°C)
Current accuracy
+0.03%FS.(15°C-35°C)
Current response time
4ms(10%-90%)
Current switching time
8ms(-90%-+90%)
Fire Fighting
Safety features: Pressure relief, door chain (standard), forced exhaust (optional) Monitoring (optional): Smoke detection, gas detection (CH, CO, H2), over-temperature protection Fire extinguishing (optional): Perfluorohexanone, water spray, flooding Safety PLC (optional): Manual/automatic fire extinguishing, remote fire extinguishing, independent alarm and power off
137,138,143,144,146,147,148
Application Scenarios
Constant temperature and humidity chamber
Delivered 4 constant temperature and humidity chambers and 1 rapid temperature change chamber to a customer in Vietnam for testing battery structural parts and electronic devices, with stable performa
Photovoltaic walk-in
Delivered 17 photovoltaic walk-ins to a customer in the photovoltaic industry for DH and HF testing in the photovoltaic industry, with stable performance and energy saving and consumption reduction.
Battery test chamber are special designed for different type of traction battery test. On the basis of standard climatic chamber, protection mechanisms are provided to different hazard level, to
Climate chamber are special designed for different type of traction battery test, On the basis of standard climatic chamber, protection mechanisms are provided to different hazard level, to ensure the
What is the temperature and humidity range of the unit?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
What are the cooling water inlet pressure and temperature requirements?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
What is the inlet pressure requirement for the impact chamber?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
What are the cooling water inlet pressure and temperature requirements?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
About how often should I change the humidity tampons?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.