Please enter search keywords!
One-layer Battery Test Chamber
Battery test chamber are special designed for different type of traction battery test. On the basis of standard climatic chamber, protection mechanisms are provided to different hazard level, to ensure the safety of company personnel, property and equipment.
-
Utilize wind field simulation optimization and high uniformity inside the box
-
Special refrigeration design, energy-saving equipment
-
Strong product versatility
-
High fire safety level
| Type |
TOH-B1000EXL |
TOH-B1200EXL |
| Interior Dimensions (W*D*Hmm) |
1000*1000*1000 |
1000*1200*1000 |
| Temperature Range |
-40~100℃ |
| Humidity range |
20~98%RH |
| Heating Rate |
(+20~100℃) ≥3℃/min |
| Cooling Rate |
(+20~-40℃) ≥1℃/min |
| Temperature Uniformity |
≤1℃ |
| Humidity Deviation |
±3.0%RH(>75%RH); ±5.0%RH(≤75%RH) |
| Temperature Deviation |
≤±2℃ |
| Temperature Fluctuation |
≤±0.5℃ |
| Humidity Fluctuation |
≤±2.0%RH |
| Temperature Accuracy |
0.1℃ |
| Humidity Accuracy |
0.1%RH |
| Output voltage |
Charging: 0-5V Discharging: 1.5-5V (battery terminal voltage) Output line within 5 meters |
| Output current |
-300A to +300A1-450A to +450A1-600A to +600A |
| Number of channels/per incubator |
8CH |
| Voltage accuracy |
±0.02%FS.(15°C-35°C) |
| Current accuracy |
+0.03%FS.(15°C-35°C) |
| Current response time |
4ms(10%-90%) |
| Current switching time |
8ms(-90%-+90%) |
| Fire Fighting |
Safety features: Pressure relief, door chain (standard), forced exhaust (optional) Monitoring (optional): Smoke detection, gas detection (CH, CO, H2), over-temperature protection Fire extinguishing (optional): Perfluorohexanone, water spray, flooding Safety PLC (optional): Manual/automatic fire extinguishing, remote fire extinguishing, independent alarm and power off
|
137,138,143,144,146,147,148
Constant temperature and humidity chamber
Delivered 4 constant temperature and humidity chambers and 1 rapid temperature change chamber to a customer in Vietnam for testing battery structural parts and electronic devices, with stable performa
Photovoltaic walk-in
Delivered 17 photovoltaic walk-ins to a customer in the photovoltaic industry for DH and HF testing in the photovoltaic industry, with stable performance and energy saving and consumption reduction.
-
Double-layer Battery Test Chamber
Battery test chamber are special designed for different type of traction battery test. On the basis of standard climatic chamber, protection mechanisms are provided to different hazard level, to
-
Triple-layer Battery Test Chamber
Climate chamber are special designed for different type of traction battery test, On the basis of standard climatic chamber, protection mechanisms are provided to different hazard level, to ensure the
137,138,143,144,146,147,148
Frequently Asked Questions
-
What is the temperature and humidity range of the unit?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
-
What are the cooling water inlet pressure and temperature requirements?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
-
What is the inlet pressure requirement for the impact chamber?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
-
What are the cooling water inlet pressure and temperature requirements?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
-
About how often should I change the humidity tampons?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.