Climate chamber are special designed for different type of traction battery test, On the basis of standard climatic chamber, protection mechanisms are provided to different hazard level, to ensure the safety of company personnel, property and equipment.
Distributed common DC bus technology converts AC power to a high-voltage DC bus via external bidirectional AC/DC units. It then provides energy to each channel through high-to-low voltage DC/DC bidirectional inverters. Each channel can also form a DC microgrid through the bus to improve conversion efficiency. Can achieve energy saving, reduce equipment maintenance as well as the footprint of the equipment.
The initial capital investment in hardware procurement (charging and discharging equipment + environmental chamber) is 10-15% lower than that of traditional cabinets.
Comprehensive electricity charges reduced by 20%-35%
The more channels, the more power it saves and the easier it is to achieve charge and discharge balance.
MAIN SPECIFICATIONS
Type
TODT-B200EXJ
TODT-B300EXJ
TODT-B600EXJ
Interior Dimensions (W*D*Hmm)
800*500*500
1200*500*500
1500*800*500
Temperature Range
-40~100°C
Humidity range
≥1℃/min(-40℃~100℃)
Heating rate
≥3℃/min(-40℃~100℃)
Temperature uniformity
< 1℃(-40℃~+100℃,No load)
Temperature deviation
< ±1°C (-40℃-+100℃)
Temperature fluctuation
<±0.5℃(No load)
Temperature accuracy
±0.1℃
noise
< 69dB
Test hole
Right side 100mm*2
Sample rack specifications
50%g/layer
Fire Protection
Safety Measures: Pressure relief, door chain (standard), strong exhaust (optional). Monitoring Functions (optional): Smoke detection, gas detection (CH, CO, H2), overtemperature
protection. Fire Extinguishing Capabilities (optional): Perfluorohexane, water spray, water submersion. Safety Programmable Logic Controller (PLC) (optional): Manual/automatic fire suppression, remote
fire suppression, independent alarm power cut-off.
140,141,143,144,146,147,148
Application Scenarios
Rapid temperature change chamber
Delivered hundreds of constant temperature and humidity chambers, rapid temperature change chambers, and hot and cold shock chambers to a customer in Vietnam for testing Apple or non-Apple electronic
Vehicle cabin
Used for high and low temperature storage, charging and discharging, low-temperature cold start, defrosting and defogging, and vehicle aging tests. The equipment has high temperature control accuracy
Battery test chamber are special designed for different type of traction battery test. On the basis of standard climatic chamber, protection mechanisms are provided to different hazard level, to
Battery test chamber are special designed for different type of traction battery test. On the basis of standard climatic chamber, protection mechanisms are provided to different hazard level, to
What is the temperature and humidity range of the unit?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
What are the cooling water inlet pressure and temperature requirements?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
What is the inlet pressure requirement for the impact chamber?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
What are the cooling water inlet pressure and temperature requirements?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
About how often should I change the humidity tampons?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.