The tested product is connected to the test platform and is heated/cooled by cooling and heating the temperature of the internal ethylene glycol solution. The corresponding temperature, flow, pressure curve can be tested and and the changes can be recorded according to the test requirements. Remote control and joint control with other equipment can be achieved by means of communication.
The temperature control range can be extended to (-45℃~150℃);
Adopt high and low temperature resistant magnetic pump, which has the advantages of low noise, large flow range and low leakage risk;
Linkage control: can be flexibly linked with charging and discharging equipment and environmental chambers;
Energy saving: precise refrigeration control, which can adjust the refrigeration capacity according to demand;
Complete safety protection measures: sensor abnormality alarm, high temperature protection, low temperature protection, high pressure protection, low pressure protection, low liquid level alarm, high liquid level alarm, heating rod anti-dry burning alarm, compressor overheat protection, circulating pump overload protection, inverter fault protection, liquid supply pressure too high protection, communication fault alarm, supply and return temperature difference too large alarm, etc.
MAIN SPECIFICATIONS
Type
TOLS-5.5-30100
TOLS-7.5-30100
TOLS-10-30100
TOLS-15-30100
TOLS-20-30100W
TOLS-40-30100W
Flow Range
1-15L/min
1-25L/min
1-25L/min
2-40L/min
2-40L/min
5-50L/min
Temperature Range
-30℃ ~ +100℃
-40℃ ~ +100℃
Temperature Control Accuracy
±0.5℃
Temperature Display
0.01℃
Cooling Medium
Ethylene glycol antifreeze, freezing point below -30℃
Flow Control Accuracy
±0.2L/min
Flow Display
0.01L/min
Pressure Control Range
0-350kPa
Pressure Control Accuracy
±2kPa
Pressure Display
0.1kPa
Heating Power
5KW
6KW
10KW
10KW
15KW
30KW
Average Cooling Rate unloaded(+85℃~-30℃)
2℃/min
6℃/min
6℃/min
6℃/min
6℃/min
8℃/min
Average Heating Rate unloaded(-30℃~+85℃)
2℃/min
6℃/min
6℃/min
6℃/min
6℃/min
8℃/min
Cooling Mode
Air cooling
Air cooling
Air cooling
Water cooling
Water cooling
Water cooling
Power Supply Requirement
AC380V/50Hz three-phase
Power Supply Interface Requirements
Five-pin aviation plug/socket
Programmed Temperature/Flow/Pressure Control
Can prepare 30 programs, each program can prepare 40 steps, program control can choose linear,
can also choose nonlinear
Curve Display
Set temperature curve, liquid supply temperature curve, liquid return temperature curve, set
pressure curve, liquid supply pressure curve, liquid return pressure curve, set flow curve, liquid supply flow
curve
Delivered 4 constant temperature and humidity chambers and 1 rapid temperature change chamber to a customer in Vietnam for testing battery structural parts and electronic devices, with stable performa
Photovoltaic walk-in
Delivered 17 photovoltaic walk-ins to a customer in the photovoltaic industry for DH and HF testing in the photovoltaic industry, with stable performance and energy saving and consumption reduction.
The tested product is connected to the test platform and is heated/cooled by cooling and heating the temperature of the internal ethylene glycol solution. The corresponding temperature, flow, pressure
What is the temperature and humidity range of the unit?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
What are the cooling water inlet pressure and temperature requirements?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
What is the inlet pressure requirement for the impact chamber?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
What are the cooling water inlet pressure and temperature requirements?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
About how often should I change the humidity tampons?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.