Chiller
The tested product is connected to the test platform and is heated/cooled by cooling and heating the temperature of the internal ethylene glycol solution. The corresponding temperature, flow, pressure curve can be tested and and the changes can be recorded according to the test requirements. Remote control and joint control with other equipment can be achieved by means of communication.
-
The temperature control range can be extended to (-45℃~150℃);
-
Adopt high and low temperature resistant magnetic pump, which has the advantages of low noise, large flow range and low leakage risk;
-
Linkage control: can be flexibly linked with charging and discharging equipment and environmental chambers;
-
Energy saving: precise refrigeration control, which can adjust the refrigeration capacity according to demand;
-
Complete safety protection measures: sensor abnormality alarm, high temperature protection, low temperature protection, high pressure protection, low pressure protection, low liquid level alarm, high liquid level alarm, heating rod anti-dry burning alarm, compressor overheat protection, circulating pump overload protection, inverter fault protection, liquid supply pressure too high protection, communication fault alarm, supply and return temperature difference too large alarm, etc.
| Type |
TOLS-5.5-30100 |
TOLS-7.5-30100 |
TOLS-10-30100 |
TOLS-15-30100 |
TOLS-20-30100W |
TOLS-40-30100W |
| Flow Range |
1-15L/min |
1-25L/min |
1-25L/min |
2-40L/min |
2-40L/min |
5-50L/min |
| Temperature Range |
-30℃ ~ +100℃ |
-40℃ ~ +100℃ |
| Temperature Control Accuracy |
±0.5℃ |
| Temperature Display |
0.01℃ |
| Cooling Medium |
Ethylene glycol antifreeze, freezing point below -30℃ |
| Flow Control Accuracy |
±0.2L/min |
| Flow Display |
0.01L/min |
| Pressure Control Range |
0-350kPa |
| Pressure Control Accuracy |
±2kPa |
| Pressure Display |
0.1kPa |
| Heating Power |
5KW |
6KW |
10KW |
10KW |
15KW |
30KW |
| Average Cooling Rate unloaded(+85℃~-30℃) |
2℃/min |
6℃/min |
6℃/min |
6℃/min |
6℃/min |
8℃/min |
| Average Heating Rate unloaded(-30℃~+85℃) |
2℃/min |
6℃/min |
6℃/min |
6℃/min |
6℃/min |
8℃/min |
| Cooling Mode |
Air cooling |
Air cooling |
Air cooling |
Water cooling |
Water cooling |
Water cooling |
| Power Supply Requirement |
AC380V/50Hz three-phase |
| Power Supply Interface Requirements |
Five-pin aviation plug/socket |
| Programmed Temperature/Flow/Pressure Control |
Can prepare 30 programs, each program can prepare 40 steps, program control can choose linear,
can also choose nonlinear |
| Curve Display |
Set temperature curve, liquid supply temperature curve, liquid return temperature curve, set
pressure curve, liquid supply pressure curve, liquid return pressure curve, set flow curve, liquid supply flow
curve |
| Alarm Light |
Three-color indicator, red: abnormal; Green: running; Yellow: Standby |
| Data Export |
USB2.0/3.0 export, standard 16G flash drive |
| Communication Interface |
CAN/RS485/RS232/LAN |
137,138,143,144,146,147,148
Constant temperature and humidity chamber
Delivered 4 constant temperature and humidity chambers and 1 rapid temperature change chamber to a customer in Vietnam for testing battery structural parts and electronic devices, with stable performa
Photovoltaic walk-in
Delivered 17 photovoltaic walk-ins to a customer in the photovoltaic industry for DH and HF testing in the photovoltaic industry, with stable performance and energy saving and consumption reduction.
-
Multi-channel Chiller
The tested product is connected to the test platform and is heated/cooled by cooling and heating the temperature of the internal ethylene glycol solution. The corresponding temperature, flow, pressure
137,138,143,144,146,147,148
Frequently Asked Questions
-
What is the temperature and humidity range of the unit?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
-
What are the cooling water inlet pressure and temperature requirements?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
-
What is the inlet pressure requirement for the impact chamber?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
-
What are the cooling water inlet pressure and temperature requirements?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
-
About how often should I change the humidity tampons?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.