Two-zone Thermal Shock Chamber
Such a series of impact test chamber adopts a structure of cold and thermal boxes and utilizes a bucket rapidly transforming specimens to the test area, so as to conduct cold and thermal shock tests.This impact mode reduces thermal load during cold and thermal impact and shortens temperature recovery time to the greatest extent.
-
It adopts color touch screen control, has a friendly interface and has parameter recording function;
-
Ultra-low defrosting times greatly improve test efficiency;
-
The basket conversion time is less than 10 seconds, and the temperature recovery time is less than 5 minutes;
-
R232 and R485 output interfaces enable remote monitoring and control of multiple units;
-
Alarm information is displayed in real time, making troubleshooting easy.
| Type |
TOL- 48EXL |
TOL- 48GXL |
TOL- 120EXL |
TOL- 120GXL |
TOL- 300EXL |
TOL- 300GXL |
TOL- 506EXL |
TOL- 506GXL |
TOL- 960EXL |
TOL- 960GXL |
TOL- 1200EXL |
TOL- 1200GXL |
| Test Area Size (W*D*Hmm) |
48L up and down (400*500*400) |
120L up and down (470*650*410) |
300L up and down (770*650*600) |
506L left and right (750*750*900) |
960L left and right (1000*800*1200) |
1200L left and right (1200*1000*1000) |
| Impact |
Low Temperature Impact Range |
-10°C ~ -40°C |
-10°C ~ -55°C |
-10°C ~ -40°C |
-10°C ~ -55°C |
-10°C ~ -40°C |
-10°C ~ -55°C |
-10°C ~ -40°C |
-10°C ~ -55°C |
-10°C ~ -40°C |
-10°C ~ -55°C |
-10°C ~ -40°C |
-10°C ~ -55°C |
| High Temperature Impact Range |
60°C~150°C |
| Pre-heating Zone Heating Rate |
>5°C/min |
| Pre-cooling Zone Cooling Rate |
>2°C/min |
| Pre-cooling Zone Temperature Range |
-10°C ~ -60°C |
-10°C ~ -70°C |
-10°C ~ -60°C |
-10°C ~ -70°C |
-10°C ~ -60°C |
-10°C ~ -70°C |
-10°C ~ -60°C |
-10°C ~ -70°C |
-10°C ~ -60°C |
-10°C ~ -70°C |
-10°C ~ -60°C |
-10°C ~ -70°C |
| Pre-heating Zone Temperature Range |
60°C~180°C |
| Dwell Time |
>30min |
| Recovery Time |
Revert to ±2°C in 5 Minutes |
| Temperature Fluctuation |
<1°C |
| Temperature Resolution |
0.1°C |
| Basket Change Time |
<10s |
| Cooling Method |
Watering-cooling |
| Standard Reference |
JESD22-A106B; GJB-150-A; MIL-STD-810G; MIL-STD-202G |
138,140,143,144,146,147,148
Photovoltaic walk-in
Delivered 17 photovoltaic walk-ins to a customer in the photovoltaic industry for DH and HF testing in the photovoltaic industry, with stable performance and energy saving and consumption reduction.
Rapid temperature change chamber
Delivered hundreds of constant temperature and humidity chambers, rapid temperature change chambers, and hot and cold shock chambers to a customer in Vietnam for testing Apple or non-Apple electronic
-
Three-zone Thermal Shock Chamber
Such a series of impact test chambers adopts a three-box structure,utilizes a pneumatic valve to switch the connection between the test area and a cold area, and between the test area and a thermal ar
138,140,143,144,146,147,148
Frequently Asked Questions
-
What is the temperature and humidity range of the unit?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
-
What are the cooling water inlet pressure and temperature requirements?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
-
What is the inlet pressure requirement for the impact chamber?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
-
What are the cooling water inlet pressure and temperature requirements?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
-
About how often should I change the humidity tampons?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.