Please enter search keywords!
Walk-in Test Chamber
The test chamber is applicable to low temperature, high temperature, high/low temperature change,constant damp-heat and high/low temperature alternating damp-heat tests, and the like of the complete machine or large-sized parts and accessories. Size and functions of the operating room may be changed according to user demands. Moreover, a blocking chamber is adopted, so that its beautiful and elegant appearance and scientific air duct design can meet demands of different customers.
-
The main part adopts modular storage panels that are easy to transport and install on site, and it is very convenient to disassemble;
-
Scientific air circulation design makes the indoor temperature (humidity) uniform and avoids any dead corners;
-
The interior of the box is made of SUS304 stainless steel and reinforced rib structure, which has better load-bearing effect;
-
Adopt European and American high-efficiency compressors and unique refrigeration circuit design, which is reliable and energy-saving;
-
It can be designed according to the size required by the user to ensure the applicability of the equipment.
| Type |
TOFH/TOF-5800EXL |
TOFH/TOF-8000EXL |
TOFH/TOF-10000EXL |
TOFH/TOF-12500EXL |
TOFH/TOF-15000EXL |
TOFH/TOF-20000EXL |
| Interior Capacity |
5800L |
8000L |
10000L |
12500L |
15000L |
20000L |
| Interior Dimensions (W*D*Hmm) |
1700*1700*2000 |
2000*2000*2000 |
2500*2000*2000 |
2500*2500*2000 |
5000*2500*2000 |
4000*2500*2000 |
| Temperature Range |
-40~150°C |
| Heating Rate |
1-5°C/min |
| Cooling Rate |
1-5°C/min |
| Humidity Range |
20~95%RH |
| Temperature Uniformity |
<2°C (-40°C~100°C) others<3°C |
| Humidity Deviation |
±3.0%RH(>75%RH); ±5.0%RH(<75%RH) |
| Temperature Deviation |
≤±2°C |
| Temperature Fluctuation |
<1°C |
| Temperature Resolution |
0.1°C |
| Humidity Resolution |
0.1%RH |
| Cooling Method |
Water-cooling |
| Standard Reference |
GB/T 2423.1; GB/T 2423.2; GB/T 2423.3; GB/T 2423.4; GB/T 5170.2; GB/T 5170.5; GB/T 11158; GB/T 10589; GB/T 10592; GB/T 10586; IEC60068-3-5 |
139,140,143,144,146,147,148
Constant temperature and humidity chamber
Delivered more than 50 devices to the world's leading laser radar brands, used for laboratory DV PV verification, performance testing, and reliability testing. Also used for product offline HT testing
Rapid temperature change chamber
Delivered hundreds of constant temperature and humidity chambers, rapid temperature change chambers, and hot and cold shock chambers to a customer in Vietnam for testing Apple or non-Apple electronic
-
Vehicle Environment Chamber
A temperature or temperature and humidity test chamber is used for vehicle testing. The test chamber can meet various vehicle tests with large loads and large heat. The temperature and temperature and humidity conditions of each test can be set using an environmental simulation control system.
-
Photovoltaic Test Chamber
The purpose of steady-state testing is to determine the performance and stability of a system or component under continuous and unchanged operating conditions in order to verify its reliability and ef
-
Storage Battery Cluster Environment Chamber
The equipment is suitable for temperature and humidity reliability testing of battery clusters and PCS equipment in the energy storage industry, and has high uniformity and large load condition testin
-
Storage Cabinet Environment Chamber
The equipment has an extra-large test space and can be used for temperature and humidity reliability testing of energy storage cabinets of various sizes, and can withstand large loads and high heat ge
-
Automotive Airbag Test Chamber
A test chamber with temperature or temperature/humidity control, used for component or whole vehicle airbag burst testing. The chamber is equipped with an independent lighting system inside. An effici
139,140,143,144,146,147,148
Frequently Asked Questions
-
What is the temperature and humidity range of the unit?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
-
What are the cooling water inlet pressure and temperature requirements?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
-
What is the inlet pressure requirement for the impact chamber?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
-
What are the cooling water inlet pressure and temperature requirements?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.
-
About how often should I change the humidity tampons?
A
Need to confirm the technical requirements according to the machine number, because the temperature and humidity range of different equipment is different.